IEC 60317-71:2020 pdf free download

admin
IEC 60317-71:2020 pdf free download

IEC 60317-71:2020 pdf free download Specifications for particular types of winding wires – Part 71: Polyester glass-fibre wound and resin or varnish impregnated, bare or enamelled round copper wire, temperature index 180 (IEC 60317-71:2020)
scope
This part of lEC 60317 specifies the requirements of polyester glass-fibre wound resinlvarnishimpregnated, bare,grade 1 or grade 2 enamelled round copper winding wire,temperatureindex 180.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot beestablished.Consequently, a class based on the requirements for temperature index and heat shock temperaturecannot be specified.
The nominal conductor diameters are specified in lEC 60317-0-10:2017,Clause 4.
2Normative references
The following documents are referred to in the text in such a way that some or all of theircontent constitutes requirements of this document. For dated references,only the editioncited applies. For undated references, the latest edition of the referenced document (includingany amendments) applies.
IEC 60317-0-10:2017,Specifications for particular types of winding wires – Part 0-10:Generalrequirements – Polyester glass-fibre ‘wound fused, unvarnished, or resin or varnishimpregnated,bare or enamelled round copper wire
3 Terms, definitions, general notes and appearance
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in lEC 60317-0-10 apply.
Is0 and lEC maintain terminological databases for use in standardization at the followingaddresses:
. IEC Electropedia: available at http://www.electropedia.orgl
. Iso Online browsing platform: available at http://www.iso.org/obp3.2General notes
3.2.1 Methods of test
Subclause 3.2.1 of IEC 60317-0-10:2017 applies. ln case of inconsistencies betweenlEC 60317-0-10 and this document,the latter shall prevail.
3.2.2Winding wire
The fibre covering shall consist of a combination of polyester and glass fibres. The glassfibres shall be electrical-grade continuous-filament glass yarn.The polyester fibre shall be ahigh-grade yarn resulting from the linear polymerization of ethylene glycol and terephthalicacid.The maximum content by weight of polyester fibre in the yarn shall not exceed 50 %.
The covering shall have one of the following grades of thickness:
– PG1 : bare conductor with 1 layer of polyester glass fibre or 2 layers of finer polyester glass fibres that together, comply with the dimensional requirements in IEC 6031 7-0-1 0;
– PG2: bare conductor with 2 layers of polyester glass fibre;
– grade 1 PG1 : enamelled grade 1 (grade 1 ) with 1 layer of polyester glass fibre (PG1 );
– grade 1 PG2: enamelled grade 1 (grade 1 ) with 2 layers of polyester glass fibre (PG2);
– grade 2 PG1 : enamelled grade 2 (grade 2) with 1 layer of polyester glass fibre (PG1 );
– grade 2 PG2: enamelled grade 2 (grade 2) with 2 layers of polyester glass fibre (PG2).
3.3 Appearance
Subclause 3.3 of IEC 6031 7-0-1 0:201 7 applies.
4 Dimensions
Clause 4 of IEC 6031 7-0-1 0:201 7 applies.
5 Electrical resistance
Clause 5 of IEC 6031 7-0-1 0:201 7 applies.
6 Elongation
Clause 6 of IEC 6031 7-0-1 0:201 7 applies.
7 Springiness
Clause 7 of IEC 6031 7-0-1 0:201 7 applies.
8 Flexibility and adherence
Clause 8 of IEC 6031 7-0-1 0:201 7 applies.
9 Heat shock
Test inappropriate.
10 Cut-through
Test inappropriate.