BS ISO 15552:2018 pdf download

admin
BS ISO 15552:2018 pdf download

BS ISO 15552:2018 pdf download.Pneumatic fluid power — Cylinders with detachable mountings, 1 000 kPa (10 bar) series, bores from 32 mm to 320 mm — Basic, mounting and accessories dimensions
1 Scope
This document establishes a metric series of basic, mounting and accessories dimensions as required for interchangeability of single or double rod pneumatic cylinders with or without provision for magnetic sensors for a maximum rated pressure of 1 000 kPa (10 bar).
It applies to pneumatic cylinders with detachable mountings.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 273, Fasteners — Clearance holes for bolts and screws
ISO 3320, Fluid power systems and components — Cylinder bores and piston rod diameters and area ratios — Metric series
ISO 4393, Fluid power systems and components — Cylinders — Basic series of piston strokes
ISO 4395, Fluid power systems and components — Cylinder piston rod end types and dimensions
ISO 5598, Fluid power systems and components — Vocabulary
ISO 16030, Pneumatic fluid power — Connections — Ports and stud ends
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 5598 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— IEC Electropedia: available at http://www.electropedia.org/
— ISO Online browsing platform: available at https://www.iso.org/obp
4 Dimensions
4.1 Basic dimensions
The basic dimensions are given in Tables 2 and 3 and shown in Figures 2 and 3. The piston rod diameter shall be larger than the thread diameter (KK) to have a shouldered male thread end.
4.2 Mounting dimensions
The mounting dimensions are given in Tables 4 to 9 and shown in Figures 4 to 9.
The sign + after letters means that the stroke is to be added to the actual dimension.
4.3 Accessories dimensions
The accessories dimensions are given in Tables 10 to 14 and shown in Figures 10 to 14.
The tolerances of dimensions dependent on stroke included in the tables apply for strokes up to and including 1 250 mm. If strokes are longer than 1 250 mm, tolerances should be selected from national standards or by agreement between the manufacturer and user.
5 Nominal stroke
5.1 The nominal strokes shall be selected from the recommended values given in ISO 4393.
5.2 The nominal stroke tolerances are given in Table 1 and shown in Figure 1.
7 Mounting types
This document includes the following mounting types as described in ISO 6099:
— MF1 Head, rectangular flange (see Table 4 and Figure 4);
— MF2 Cap, rectangular flange (see Table 4 and Figure 4);
— MP2 Cap, detachable clevis (see Table 5 and Figure 5);
— MP4 Cap, detachable plain eye (see Table 6 and Figure 6);
— MP6 Cap, detachable eye with spherical bearing (see Table 7 and Figure 7);
— MS1 End angles (see Table 8 and Figure 8);
— MT4 Intermediate trunnion (male) fixed or mobile (see Table 9 and Figure 9).