IEC 61857-21:2009 pdf free download

admin
IEC 61857-21:2009 pdf free download

IEC 61857-21:2009 pdf free download Electrical insulation systems – Procedures for thermal evaluation – Part 21: Specific requirements for general-purpose models – Wire-wound applications
1 Scope
This part of lEC 61851, together with part 1, gives the requirements for a.c. electric vehiclecharging stations for conductive connection to an electric vehicle,with a.c. supply voltagesaccording to lEC 60038 up to 69o v.
This standard does not cover all safety aspects related to maintenance.
The scope of this part of lEC 61851 does not cover box type assemblies with socket-outlets,installed for the purpose of delivering energy to the vehicle,which have no charging controlfunctions.
Normative references
The following normative documents contain provisions which,through reference in this text,constitute provisions of this part of lEC 61851.For dated references,subsequent amendmentsto, or revisions of,any of these publications do not apply. However,parties to agreementsbased on this part of iEc 61851 are encouraged to investigate the possibility of applying themost recent editions of the normative documents indicated below.For undated references, thelatest edition of the normative document referred to applies. Members of lSO and lEC maintainregisters of currently valid International Standards.
IEC 60038:1983,IEC standard voltages
IEC 60068-2-1:1990,Environmental testing – Part 2 : Tests – Tests A : ColdIEC 60068-2-2:1974,Environmental testing – Part 2:Tests – Tests B: Dry heat
IEC 60068-2-3:1969,Environmental testing – Part 2:Tests -Test Ca: Damp heat, steady state
IEC 60068-2-5:1975,Environmental testing – Part 2:Tests – Test Sa: Simulated solar radiationat ground level
IEC 60068-2-14:1984,Environmental testing – Part 2:Tests -Test N: Change of temperature
IEC 60068-2-30:1980,Environmental testing – Part 2:Tests -Test Db and guidance: Dampheat, cyclic (12 + 12-hour cycle)
IEC 60068-2-52:1996,Environmental testing – Part 2: Tests – Test Kb: Salt mist,cyclic(sodium chloride solution)
IEC 60068-2-75:1997,Environmental testing – Part 2:Tests – Test Eh: Hammer tests
IEC 60364-4-43:1977,Electrical installations of buildings – Part 4: Protection for safety -Chapter 43: Protection against overcurrent
IEC 60364-4-443:1995,Electrical installations of buildings – Part 4: Protection for safety -Chapter 44: Protection against overvoltages – Section 443: Protection against overvoltages ofatmospheric origin or due to switching
Amendment 1 (1998) 1)
IEC 60439-1:1999 Low-voltage switchgear and controlgear assemblies – Part 1: Type-testedand partially type-tested assemblies
IEC 60529:1989,Degrees of protection provided by enclosures (IP Code)
IEC 60664-1:1992,Insulation coordination for equipment within low-voltage systems – Part 1:Principles, requirements and tests
IEC 60950:1999,Safety of information technology equipment
IEC 61000-2-2:1990,Electromagnetic compatibility (EMC) – Part 2: Environment – Compati-bility levels for low-frequency conducted disturbances and signalling in public low-voltagepower supply systems
IEC 61000-3-2:2000,Electromagnetic compatibility(EMC) – Part 3-2: Limits – Limits forharmonic current emissions (equipment input current s16 A per phase)
IEC 61000-4-1:2000,Electromagnetic compatibility (EMC) – Part 4-1: Testing and measure-ment techniques – Overview of iEC 610oo-4 series
IEC 61000-4-2:1995, Electromagnetic compatibility(EMC) – Part4-2: Testingandmeasurement techniques – Section 2: Electrostatic discharge immunity test – Basic EMCpublication 2)
Amendment 1 (1998)Amendment 2 (2ooo)
IEC 61000-4-3:1995, Electromagnetic compatibility (EMC) – Part 4: Testing and measurementtechniques – Section 3:Radiated, radio-frequency, electromagnetic field immunity test 3)
Amendment 1 (1998)
Amendment 2 (2ooo)
IEC 61000-4-4:1995,Electromagnetic compatibility (EMC) – Part 4: Testing and measurementtechniques – Section 4: Electrical fast transient/burst immunity test – Basic EMC publicationAmendment 1 (2000)